Laboratory Procedures
Laboratory & QA/QC

Laboratory Procedures

132 questions · ~13 minutes · instant grading with full explanations

All quizzes
Laboratory & QA/QC · 132 questions · ~13 min
0 / 132 answered · 0 correct
  1. 01

    The BOD5 test incubation is:

  2. 02

    A BOD5 result is generally considered valid only when:

  3. 03

    If a BOD bottle ends with DO below ~1 mg/L, you should:

  4. 04

    Carbonaceous BOD (CBOD) uses a nitrification inhibitor to:

  5. 05

    Why must BOD dilution water contain nutrients and a buffer?

  6. 06

    Glucose-glutamic acid BOD check (a known 300 mg/L standard) typically yields ~198 mg/L; if your lab gets 120 mg/L, suspect:

  7. 07

    BOD results are reported in:

  8. 08

    A BOD blank (seed-free dilution water incubated) should:

  9. 09

    Seeding BOD samples with settled domestic effluent is used to:

  10. 10

    When seeding, you must:

  11. 11

    Chlorinated samples can give falsely low BOD because chlorine:

  12. 12

    Why is BOD5 sometimes performed with multiple dilutions?

  13. 13

    BOD5 final results must consider:

  14. 14

    The COD test oxidizes organics using:

  15. 15

    COD is usually:

  16. 16

    Chloride interference in COD is controlled by adding:

  17. 17

    COD is most useful when:

  18. 18

    A high COD/BOD ratio usually indicates:

  19. 19

    Typical COD/BOD ratio for domestic wastewater is roughly:

  20. 20

    Which test does NOT involve microorganisms?

  21. 21

    Which reagent is added to COD digestion as a catalyst?

  22. 22

    TSS is measured using which filter?

  23. 23

    What temperature is the TSS filter dried at?

  24. 24

    Volatile suspended solids (VSS) are determined by:

  25. 25

    Fixed (non-volatile) suspended solids are mostly:

  26. 26

    Total Solids (TS) equals:

  27. 27

    TDS is determined by:

  28. 28

    Settleable solids are reported in:

  29. 29

    Settleable solids are measured using:

  30. 30

    A TSS result is suspiciously low after a high-flow event; the most likely lab/field issue is:

  31. 31

    Standard Methods recommends which best practice for TSS analysis?

  32. 32

    Dissolved oxygen (DO) is most commonly measured with:

  33. 33

    A DO probe should be calibrated by:

  34. 34

    The Winkler method measure DO via:

  35. 35

    The azide modification of the Winkler method is used to:

  36. 36

    Why must a DO sample be analyzed immediately?

  37. 37

    Higher temperature affects DO readings by:

  38. 38

    A membrane DO probe membrane fouling typically causes:

  39. 39

    A DO reading that suddenly reads max on a membrane probe most likely indicates:

  40. 40

    A pH meter must be calibrated with at least how many buffers?

  41. 41

    Common pH calibration buffers are:

  42. 42

    pH is best defined as:

  43. 43

    A neutral solution at 25 °C has a pH of:

  44. 44

    pH meters should:

  45. 45

    Which buffer would you choose to calibrate before measuring a pH ~6.5 sample?

  46. 46

    Erratic pH readings often indicate:

  47. 47

    For pH, a grab sample analyzed on-site is recommended because:

  48. 48

    Turbidity is reported in:

  49. 49

    A turbidimeter measures turbidity by:

  50. 50

    Turbidity standards are made from:

  51. 51

    Low-turbidity measurements require:

  52. 52

    A turbidity rise in final effluent often signals:

  53. 53

    Turbidity is a useful in-line surrogate for:

  54. 54

    Alkalinity is typically reported as:

  55. 55

    Alkalinity titration end-point pH is commonly:

  56. 56

    The dominant form of alkalinity in raw wastewater is:

  57. 57

    Hardness is most commonly measured by:

  58. 58

    Hardness is reported as:

  59. 59

    Carbonate (CO₃²⁻) hardness contributes to alkalinity:

  60. 60

    Which contributes to 'non-carbonate' hardness?

  61. 61

    Alkalinity changes during nitrification because:

  62. 62

    Ammonia is commonly analyzed by:

  63. 63

    Nitrate is commonly analyzed by:

  64. 64

    Total phosphorus (TP) requires:

  65. 65

    Orthophosphate (reactive P) is measured:

  66. 66

    TKN (Total Kjeldahl Nitrogen) requires:

  67. 67

    TKN consists of:

  68. 68

    An ion-selective electrode (ISE) for nitrate requires:

  69. 69

    Colorimetric nutrient methods are sensitive to:

  70. 70

    For nutrient analyses, the type of preservation is typically:

  71. 71

    Holding time for ammonia (preserved) is commonly up to:

  72. 72

    Fecal coliform compliance is most commonly measured by:

  73. 73

    On a membrane-filter coliform plate, you count:

  74. 74

    Which is a methodology for coliform analysis using a defined substrate?

  75. 75

    Why does chlorine disinfection monitoring use a grab sample analyzed immediately?

  76. 76

    An MPN (Most Probable Number) result is:

  77. 77

    Which is true about IDEXX Quanti-Tray?

  78. 78

    Sterile sampling technique for bacteriology requires:

  79. 79

    Bacteriological samples have a very short holding time, commonly:

  80. 80

    A grab sample is:

  81. 81

    A 24-hour composite sample is typically built from:

  82. 82

    For a parameter that changes rapidly (e.g., chlorine residual), the best sample type is a:

  83. 83

    For BOD5 and TSS compliance, the typical sample type is a:

  84. 84

    Cooling samples to 4 °C during compositing/storage is done to:

  85. 85

    Chain-of-custody documents:

  86. 86

    Every analytical parameter has:

  87. 87

    Sample preservation with acid (H₂SO₄ to pH <2) is used for:

  88. 88

    Samples for metals analysis are usually preserved by:

  89. 89

    A 'representative' sample is one that:

  90. 90

    Why is glassware for nutrient analysis usually acid-washed?

  91. 91

    For BOD, the sample temperature should:

  92. 92

    A method blank verifies:

  93. 93

    A laboratory duplicate checks:

  94. 94

    A laboratory-fortified blank (LFB) or known standard checks:

  95. 95

    A matrix spike (MS) checks:

  96. 96

    Control charts are used to:

  97. 97

    Reagent water (Type I/II) is required for nutrient and metals analyses to:

  98. 98

    A balance used for TSS/VSS must be:

  99. 99

    Calibration verification should be performed:

  100. 100

    A sample sent to a reference lab for a duplicate is part of:

  101. 101

    Spikes, blanks, and duplicates should be run at a frequency that:

  102. 102

    Acids should always be added to water, never water to acid, to:

  103. 103

    Reagent-grade solvents and acids require handling using:

  104. 104

    SDS files in the lab should be:

  105. 105

    An emergency eyewash/safety shower must be:

  106. 106

    Mercury and other heavy-metal wastes must be:

  107. 107

    Glassware with broken glass should be:

  108. 108

    Phenolphthalein alkalinity vs total alkalinity differ by:

  109. 109

    A BOD seed source should be:

  110. 110

    The IDEXX Colilert test detects E. coli through:

  111. 111

    Membrane filter fecal coliform incubation is at:

  112. 112

    Fecal coliform reporting units commonly are:

  113. 113

    Method Detection Limit (MDL) is:

  114. 114

    Reportable results below the MDL are usually:

  115. 115

    Relative Percent Difference (RPD) for laboratory duplicates is commonly flagged when it:

  116. 116

    A continuing calibration verification (CCV) failing outside acceptance means:

  117. 117

    Composite samplers must be:

  118. 118

    For TSS, filtering too small a sample volume can cause:

  119. 119

    For very turbid samples in TSS, the operator should:

  120. 120

    A BOD sample containing residual chlorine should be:

  121. 121

    For DO, the sample should be collected:

  122. 122

    Alkalinity to pH 4.5 endpoint uses which standard titrant?

  123. 123

    Hardness EDTA titration endpoint color change is:

  124. 124

    Nitrate by cadmium reduction requires:

  125. 125

    TSS/VSS results should be calculated from:

  126. 126

    A 'field blank' verifies:

  127. 127

    For very low-level nutrient analyses (e.g., TP < 0.1 mg/L), the lab must:

  128. 128

    Samples for dissolved metals/orthophosphate are typically:

  129. 129

    pH electrodes are stored:

  130. 130

    Glass pipettes for trace work are usually:

  131. 131

    Chlorine residual by DPD is read:

  132. 132

    Lab QA/QC documentation should be:

Next Up